468 research outputs found

    An experimental and analytical study of visual detection in a spacecraft environment, 1 July 1968 - 1 July 1969

    Get PDF
    Predicting star magnitude which can be seen with naked eye or sextant through spacecraft windo

    Mie scattering by a charged dielectric particle

    Full text link
    We study for a dielectric particle the effect of surplus electrons on the anomalous scattering of light arising from the transverse optical phonon resonance in the particle's dielectric constant. Excess electrons affect the polarizability of the particle by their phonon-limited conductivity, either in a surface layer (for negative electron affinity) or the conduction band (for positive electron affinity). We demonstrate that surplus electrons shift an extinction resonance in the infrared. This offers an optical way to measure the charge of the particle and thus to use it in a plasma as a minimally invasive electric probe.Comment: 5 pages, 5 figures, accepted manuscrip

    Point defect dynamics in bcc metals

    Full text link
    We present an analysis of the time evolution of self-interstitial atom and vacancy (point defect) populations in pure bcc metals under constant irradiation flux conditions. Mean-field rate equations are developed in parallel to a kinetic Monte Carlo (kMC) model. When only considering the elementary processes of defect production, defect migration, recombination and absorption at sinks, the kMC model and rate equations are shown to be equivalent and the time evolution of the point defect populations is analyzed using simple scaling arguments. We show that the typically large mismatch of the rates of interstitial and vacancy migration in bcc metals can lead to a vacancy population that grows as the square root of time. The vacancy cluster size distribution under both irreversible and reversible attachment can be described by a simple exponential function. We also consider the effect of highly mobile interstitial clusters and apply the model with parameters appropriate for vanadium and α−\alpha-iron.Comment: to appear in Phys. Rev.

    Observation of a New Type of Low Frequency Waves at Comet 67P/Churyumov-Gerasimenko

    Get PDF
    We report on magnetic field measurements made in the innermost coma of 67P/Churyumov-Gerasimenko in its low activity state. Quasi-coherent, large-amplitude (ÎŽB/B∌1\delta B/B \sim 1), compressional magnetic field oscillations at ∌\sim 40 mHz dominate the immediate plasma environment of the nucleus. This differs from previously studied comet-interaction regions where waves at the cometary ion gyro-frequencies are the main feature. Thus classical pick-up ion driven instabilities are unable to explain the observations. We propose a cross-field current instability associated with newborn cometary ion currents as a possible source mechanism.Comment: 6 pages, 3 Figure

    Plutonium stabilization in zircon: Effects of self-radiation

    Full text link
    Zircon (ZrSiO4)(ZrSiO4) is the most thoroughly studied of all candidate ceramic phases for the stabilization of plutonium. Self-radiation damage from α-decay of the 239Pu,239Pu, which releases a 5.16 MeV α-particle and a 0.086 MeV 235U235U recoil nucleus, can significantly affect the structure and properties of zircon. Recent computer simulations using energy minimization techniques indicate that the lowest energy configuration occurs for a defect cluster composed of two near-neighbor Pu3+Pu3+ substitutions on Zr4+Zr4+ sites and a neighboring charge-compensating oxygen vacancy. © 2000 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87571/2/18_1.pd

    Effect of Perioperative Lipid Status on Clinical Outcomes after Cardiac Surgery

    Get PDF
    Abstract Patients undergoing cardiac surgery are at increased cardiovascular risk, which includes altered lipid status. However, data on the effect of cardiac surgery and cardiopulmonary bypass (CPB) on plasma levels of key lipids are scarce. We investigated potential effects of CPB on plasma lipid levels and associations with early postoperative clinical outcomes. This is a prospective bio-bank study of patients undergoing elective cardiac surgery at our center January to December 2019. The follow-up period was 1 year after surgery. Blood sampling was performed before induction of general anesthesia, upon weaning from cardiopulmonary bypass (CPB), and on the first day after surgery. Clinical end points included the incidence of postoperative stroke, myocardial infarction, and death of any cause at 30 days after surgery as well as 1-year all-cause mortality. A total of 192 cardiac surgery patients (75% male, median age 67.0 years (interquartile range 60.0–73.0), median BMI 26.1 kg/m2 (23.7–30.4)) were included. A significant intraoperative decrease in plasma levels compared with preoperative levels (all p < 0.0001) was observed for total cholesterol (TC) (Cliff’s delta d: 0.75 (0.68–0.82; 95% CI)), LDL-Cholesterol (LDL-C) (d: 0.66 (0.57–0.73)) and HDL-Cholesterol (HDL-C) (d: 0.72 (0.64–0.79)). At 24h after surgery, the plasma levels of LDL-C (d: 0.73 (0.650.79)) and TC (d: 0.77 (0.69–0.82)) continued to decrease compared to preoperative levels, while the plasma levels of HDL-C (d: 0.46 (0.36–0.55)) and TG (d: 0.40 (0.29–0.50)) rebounded, but all remained below the preoperative levels (p < 0.001). Mortality at 30 days was 1.0% (N = 2/192), and 1-year mortality was 3.8% (N = 7/186). Postoperative myocardial infarction occurred in 3.1% of patients (N = 6/192) and postoperative stroke in 5.8% (N = 11/190). Adjusting for age, sex, BMI, and statin therapy, we noted a protective effect of postoperative occurrence of stroke for pre-to-post-operative changes in TC (adjusted odds ratio (OR) 0.29 (0.07–0.90), p = 0.047), in LDL-C (aOR 0.19 (0.03–0.88), p = 0.045), and in HDL-C (aOR 0.01 (0.00–0.78), p = 0.039). No associations were observed between lipid levels and 1-year mortality. In conclusion, cardiac surgery induces a significant sudden drop in levels of key plasma lipids. This effect was pronounced during the operation, and levels remained significantly lowered at 24 h after surgery. The intraoperative drops in LDL-C, TC, and HDL-C were associated with a protective effect against occurrence of postoperative stroke in adjusted models. We demonstrate that the changes in key plasma lipid levels during surgery are strongly correlated, which makes attributing the impact of each lipid to the clinical end points, such as postoperative stroke, a challenging task. Large-scale analyses should investigate additional clinical outcome measures

    Tuning a Circular p-n Junction in Graphene from Quantum Confinement to Optical Guiding

    Full text link
    The motion of massless Dirac-electrons in graphene mimics the propagation of photons. This makes it possible to control the charge-carriers with components based on geometrical-optics and has led to proposals for an all-graphene electron-optics platform. An open question arising from the possibility of reducing the component-size to the nanometer-scale is how to access and understand the transition from optical-transport to quantum-confinement. Here we report on the realization of a circular p-n junction that can be continuously tuned from the nanometer-scale, where quantum effects are dominant, to the micrometer scale where optical-guiding takes over. We find that in the nanometer-scale junction electrons are trapped in states that resemble atomic-collapse at a supercritical charge. As the junction-size increases, the transition to optical-guiding is signaled by the emergence of whispering-gallery modes and Fabry-Perot interference. The creation of tunable junctions that straddle the crossover between quantum-confinement and optical-guiding, paves the way to novel design-architectures for controlling electronic transport.Comment: 16 pages, 4 figure

    Initial experience with minimally invasive extracorporeal circulation in coronary artery bypass graft reoperations

    Get PDF
    AIMS OF THE STUDY Minimally invasive extracorporeal circulation (MiECC) is an established alternative to conventional extracorporeal circulation (CECC) in coronary artery bypass graft surgery (CABG), but data on its use in cardiac reoperations are limited. We aimed to analyse perioperative morbidity and mortality in adult patients undergoing reoperations for isolated CABG using either CECC or MiECC circuits at our centre. METHODS AND RESULTS In a single centre retrospective observational study of all adult patients undergoing cardiac reoperations for isolated CABG between 2004 and 2016, we identified 310 patients, and excluded those who received concomitant cardiac procedures (n = 205). Of the remaining 105 patients, 47 received isolated redo-CABG using MiECC, and 58 received CECC. Propensity score modelling was performed, and inversed probability treatment analysis was used between the treatment groups. Primary endpoint was 30-day all-cause mortality. Secondary endpoints included major adverse cardiac or cerebrovascular events or need for conversion to CECC. Groups were comparable, apart from a higher incidence of NYHA class III or higher in CECC group (33.5% vs 8.6%, p= 0.004). Shorter times for operation, cardiopulmonary bypass and aortic cross-clamp were observed in the MiECC group. The incidence of postoperative atrial fibrillation was significantly lower with MiECC (22.1%, p = 0.012). No significant difference was observed in all-cause 30-day mortality between the MiECC and CECC groups (6.8% vs. 8.3%, p = 0.81). CONCLUSION We found no difference in overall mortality between CECC and MiECC in patients undergoing reoperation for isolated CABG. Furthermore, we found no indication of differences in most outcomes between extracorporeal circuit types. In the case of redo-CABG, MiECC could provide an alternative strategy

    Third-generation continuous-flow left ventricular assist devices: a comparative outcome analysis by device type.

    Get PDF
    AIMS Continuous-flow left ventricular assist devices (CF-LVADs) have become a standard of care in end-stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices. METHODS AND RESULTS Investigator-initiated retrospective-observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all-cause mortality and heart transplantation. Secondary endpoints included device-related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≄24 h), device-related major infection (excluding driveline infections), major device malfunctions leading to re-intervention or partial device exchange (pump failure, outflow-graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re-interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender, body mass index (BMI), and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Out of 106 primary CF-LVAD implantations, 36 (34%) received HM3 and 70 (66%) received HW. Median follow-up was 1.48 years [interquartile range 0.67, 2.41]. HM3 was more often implanted in men (91.7% vs. 72.9%, P = 0.024); patients were older (median 61 years [54, 66.5] vs. 52.5 years [43, 60], P < 0.001), had a higher BMI (median 26.7 kg/m2 [23.4, 29.0] vs. 24.3 kg/m2 [20.7, 27.4], P = 0.013), had more comorbidities, and were more likely targeted for destination therapy (36.1% vs. 14.3%, P = 0.010). Death occurred in 33.3% of HM3 patients, compared with 22.9% of HW patients, P = 0.247 (probability of survival at 4 years, 54.7% vs. 74.1%, P = 0.296). After adjustment for confounders, we observed a significant six-fold risk increase in device malfunctions for HW [hazard ratio (HR) 6.49, 95% confidence interval (CI) [1.89, 22.32], P = 0.003], but no significant differences in pump thrombosis (P = 0.173) or overall survival (P = 0.801). CONCLUSIONS Comparing midterm outcomes between HM3 and HW for LVAD support from a prospective registry, HW patients had a significantly higher risk of device malfunctions. No significant differences were evident between devices in overall survival and in respect to most outcomes
    • 

    corecore